Home | Company | Information | Contacts | 888.972.2728
AV Tuners | Digital Signage | Display Control | AV Tools | Downloads
HD Tuners
232-ATSC
TV Tuners
232-STS S-Video TV
232-STSi PAL TV
232-STA Stereo TV
232-MTA Mono TV
Software
Tuner Helper
Firmware Updates
Accessories
Rack Mount Kits
IC-RC Wireless Remote
IR-RXC IR Sensor

232-ATSC HDTV Tuner


View larger image

Installation

RS-232/Closure Wiring

All drawings show pin numbers relative to a PC COM port or typical control system RS-232 ports. Pins 4 and 9 are momentary closures to GND (5). A fully-wired null modem cable can be used for RS-232 control, a DTR signal on Pin 4 will not trigger a Channel Up commmand.

Up to nine tuners can be daisy-chained from one RS-232 control port. Remember that you will need to use the Unit# address in your programming when you control more than one tuner from the same control port.

Set the first unit in the RS-232 chain to the highest Unit#, then wire in sequence to the last tuner in the chain. The reason for this is that CR tuners use an intelligent data bus - the highest number tuner receives all commands, and then passes on commands addressed to tuners with lower unit numbers. The next tuner in the chain does the same, and so on until the last unit.

IR Control

The 232-ATSC IR codes are avialable in AMX, Crestron, and Prono formats, and include discrete power on, off commands. To review command options, open the Pronto list in the HTML file. Download from Resources menu on the right.

© 2008 Contemporary Research Corporation. All rights reserved.